TROUBLESHOOTINGRMP-424

As soon as a problem is noticed, immediately remove the disposable plastic mixer nozzle and try dispensing material. This may prevent or purge material cross-over if it has not already hardened. After the static mixer is removed, THEN check the following:

  1. Is the mixer nozzle plugged? (material set up)
  2. Is there sufficient air supply?
  3. Is there sufficient material supply?
  4. Is the air regulator set at desired pressure?

Do a ratio check at the dispense valve:

  1. Check to see if there is flow from both pumps.
  2. Check to see if the pump outlet valve is cutting off material and also that it is not sucking air in the return stroke.
  3. Check phasing. Is one material flowing before the other?
  4. Measure volume output of each material.

If ratio check is not correct, the problem is in the meter.

  • Supply blockage or low material. (viscosity too high)
  • Pump seal worn.
  • Outlet check valve not sealing.
  • Air entrapped in pressure tube.

Click Here for Printable Troubleshooting Guide