Periodic Maintenance: RMP-424
Daily Maintenance
- Clean and lubricate exposed pump rods.
- Remove and clean any material residue or film with compatible solvent (damp pad only - do not pour solvent)
- Lubricate with compatible lubricants. (Material film on shaft is normal)
- Check air supply for clean air.
- Ratio Check Test
- Remove the retainer cap or mixer nozzle.
- Trigger applicator; two separate beads of material will appear; compare for correct volume.
- Seal/Pump Check Test
- Turn air pressure regulator down all the way
- Place a waste container or drop cloth under the purge valve (ball valve below gauge) and open the valve opposite the pump to be checked. EXAMPLE: to check "A" open "B".
- Disconnect the air line, (black or clear 5/32" tube) coming from the unidirectional (gray) valve, at the tube fitting on the 4-way valve the tube connects to. Plug or pinch off the tube. This will prevent the automatic dispense valve from opening.
- Trigger or actuate the unit and slowly turn the pressure up until rods move forward and stall against pressure (pressure gauge on "A" side should read 300-500 psi; "B" gauge should read "0" psi). If it stalls and pressure registers, the pressure seal is good. If the system does not stall, and it takes a long cycle or an additional cycle, there is either air trapped in the pressure tube, the pressure seal is bad, or material is not being supplied.
- Release signal; cylinder will move back and pressure should hold on gauge. If pressure drops, outlet check valve is failing. Clean or replace.
- Repeat sequence on other side closing "B" and opening "A" valve. This will check other side.
|