Periodic Maintenance: GRP-075
Daily Maintenance
- Clean and Lubricate Geroller Pumps.
- Remove and clean any material residue or film with compatible solvent (damp pad only - do not pour solvent).
- Lubricate with compatible lubricants.
- Check for material leaking from pump shaft seals.
- Check air supply for clean air and empty or change filter.
Weekly Maintenance
- Clean and lubricate metering pumps and dispense valve.
- Remove and clean any material residue or film with compatible solvent (damp pad only - do not pour solvent).
- Check air supply for clean air and empty or change filter.
- Perform Ratio Check - Checking can be done at either the pump outlet assembly, if applicable, or at the applicator head area.
- Remove the retainer cap or static mixer nozzle.
- Trigger applicator; two separate beads of material will appear; compare for correct volume.
- Check dessicant canister if supplied. Replace or bake to refresh if the crystals are discolored.