Periodic MaintenanceGMP-075

Daily Maintenance

  • Clean and Lubricate Gerotor Pumps.
    1. Remove and clean any material residue or film with compatible solvent (damp pad only - do not pour solvent).
    2. Lubricate with compatible lubricants.
    3. Check for material leaking from pump shaft seals.
    4. Check air supply for clean air and empty or change filter.

Weekly Maintenance

  • Clean and lubricate metering pumps and dispense valve.
  • Remove and clean any material residue or film with compatible solvent (damp pad only - do not pour solvent).
  • Check air supply for clean air and empty or change filter.
  • Perform Ratio Check - Checking can be done at either the pump outlet assembly, if applicable, or at the applicator head area.
    • Remove the retainer cap or static mixer nozzle.
    • Trigger applicator; two separate beads of material will appear; compare for correct volume.
  • Check dessicant canister if supplied. Replace or bake to refresh if the crystals are discolored.